Hantek 1008c Automotive Oscilloscope/DAQ/Programmable Generator Handheld 8 Channels USB Oscilloscopes with Auto Ignition Probe

$145.79$167.79

  Hurry up! Sale end in:
+ -
  Estimated Delivery: Oct 05 – Oct 10
  ... people are viewing this right now

  Share

Hantek 1008C Automotive Oscilloscope USB 8 Channels PC Based Storage Digital Multimeter Osciloscopio Logic Analyzer Diagnostic-tool

  • Cost-effective Hantek PC USB 8CH Automotive Diagnostic Oscilloscope/DAQ/Programmable Generator: Highly efficient and cost -effective;

  • 8 channels oscilloscope for vehicle testing;

  • Auto Ignition Probe;

  • 2.4MSa/s real time sampling rate, 12bit vertical resolution;

  • spectrum analysis function;

  • 10mV/div to 5V/div input sensitivity;

  • DAQ card function;

  • 8 channels programmable generator which can analog signals of crankshaft, camshaft, etc.

(1) Vehicle Testing

  • First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition

  • Ignition: primary and secondary

  • Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position

  • Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus

  • Performer: Petrol/Diesel

  • Starter and charging circuits

(2) Oscilloscope

  • 8 channels oscilloscope, 2.4MSa/s real time sampling rate

  • 12 bits vertical resolution, spectrum analysis function

(3) Programmable Generator

  • 8 channels programmable generator

  • Can analog signals of crankshaft, camshaft etc.

(4) Others

  • USB 2.0 interface plug and play, and no need extra power supply;

  • More than 20 types of automatic testing function, a similar interface with benchtop oscilloscope, easy to use;

NOTE: Software support: Windows NT, Window 2000, Windows XP, VISTA, Windows 7,Window 8,Window 10

Model

Hantek1008C

Oscilloscope Mode

Vertical

Analog Channel

8

Input Impedance

Resistance: 1MΩ

Input Sensitivity

10mV/div to 5V/div

Input Coupling

DC

Resolution

12 bits

Horizontal

Memory Depth

4K

Max. Input

400V (DC+AC Peak)

Real-Time Sampling Rate

2.4MSa/s

Time Base Range

1ns/div to 20000s/div(1-2-5 sequences)

Time Base Precision

±50ppm

Trigger

Source

CH1, CH2,CH3,CH4, CH5, CH6,CH7,CH8

Mode

Edge

X-Y Mode

X-Axis Input

CH1

Y-Axis Input

CH2

Cursors and Measurement

Voltage Measurement

Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase,Vavg, Vrms, Vcrms, Preshoot, Overshoot

Time Measurement

Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle

Cursors Measurement

Horizontal ,Vertical, Track, Auto Measure Modes

Waveform Signal Process

+,- , x,÷, FFT, Invert

Voltage Range

10mV to 5V/div @ x 1 probe

100mV to 50V/div @ x 10 probe

10V to 5000V/div @ x 1000 probe

100V to 50000V/div @ x 10000 probe

200mV to 100V/div @ 20:1

Current Range

100mA to 50.0A/div @ CC65(20A)

1000mA to 500.0A/div @ CC65(65A)

1A to 100.0A/div @ CC650(60A)

10A to 1000.0A/div @ CC650(650A)

1A to 200.0A/div @CC1100(100A)

10A to 2000.0A/div @CC1100(1100A)

Cursor

Time/frequency difference, voltage difference

FFT

Rectangular, Hanning, Hamming, Blackman Window

Math

Addition, subtraction, multiplication, division

Programmable Generator

Channel

8

Output Level

LVTTL

Frequency Range

0-250kHz

Interface

USB 2.0

Power

No need extra power supply

Measurement

Size

185 x 150 x 27 (mm)

Weight

0.35KG

  • 1 x 1008C DAQ oscilloscope

  • 8 x Crocodile probes/cabl

  • 1 x USB Cable

  • 1 x CD (driver etc.)

  • 1 x Bag

  • Function Selection

    There are three functions of vehicle diagnosis, oscilloscope and signal generator, including 78 types of vehicle diagnosis function.

    One Button Screenshot

    Save the current waveform and generate pictures. Storage location is optional and easy to find.

    Reference Waveform

    Over 80 types of standard reference waveform inside and can be callout or close with one button. It is convenient to be compared.

    Measurement Method

    20 types of automatic measurement method which can be callout or close with one button. It is convenient and visual to read out the result.

    Print

    The result can be printed with one button and generate diagnosis report which is easy to be saved and recorded.

    REF Comparison Waveform

    The user can save the waveform as REF format and callout it again when you need to compare the two waveforms catched in different time.

    Data Storage

    The diagnosis result can be saved as the format of txt, csv, rfc, xls, doc, jpg and etc. It is convenient to be checked and compared later.

    8CH Vehicle Diagnosis

    8CH signal can be measured simultaneously. The measurement voltage of each channel can be adjusted independently. You can choose to open or close each channel.

    Waveform Record

    Support to record and replay the waveform. The waveform can be save into the computer hard disk and easy to read. There is no limit to the record time which can long-time measure and record the waveform for troubleshooting.

    Multilanguage Support

    Support the display surface in Chinese, English, German language, and it can be switched freely.

    Cursor Measurement

    Support 4 types of cursor measurement mode -cross,track, horizontal, and vertical.It’s easy to read out the time and voltage of irregular signal.

    Color and Lightness

    The background color is optional as user’s preference. And the lightness of waveform and gridding is settable.

    USB Communication

    USB2.0 power supply + communication interface, plug and play, and support hot plugging.

    Signal Generator

    Signal generator function, can simulate crankshaft and camshaft signal.

Based on 0 reviews

0.00 Overall
0%
0%
0%
0%
0%

Only logged in customers who have purchased this product may leave a review.

Reviews

There are no reviews yet.

SKU: C07QFURP0P2R Category:
Close My Cart
Close Wishlist
Recently Viewed Close
Close

Close
Navigation
Categories